27 Temmuz 2018 Cuma

Hp Proliant - Red Hat / OEL 7 - bios has corrupted hw-pmu resources error

Environment: HP Proliant DL380 G8
Operating System: Oracle Enterprise Linux 7.5

Symptoms: After installation during reboot just before loading operating system blank screen appears with mesage "bios has corrupted hw-pmu resources error" and reboots.

Workaround:  https://www.serveradminblog.com/2015/04/firmware-bug-the-bios-has-corrupted-hw-pmu-resources

Affected servers:
– All ProLiant Gen8 Servers
– ProLiant DL580 G7
– ProLiant BL620 G7
– ProLiant BL680 G7
How to disable “Processor Power and Utilization Monitoring”:
– enter BIOS (press F9 during boot)
– press CTRL+A (Service Option is hidden by default)
– select “Service Options” -> Processor Power and Utilization Monitoring -> Disable
Press F10 to save and exit and reboot the server.