Operating System: Oracle Enterprise Linux 7.5
Symptoms: After installation during reboot just before loading operating system blank screen appears with mesage "bios has corrupted hw-pmu resources error" and reboots.
Workaround: https://www.serveradminblog.com/2015/04/firmware-bug-the-bios-has-corrupted-hw-pmu-resources
Affected servers:
– All ProLiant Gen8 Servers
– ProLiant DL580 G7
– ProLiant BL620 G7
– ProLiant BL680 G7
– All ProLiant Gen8 Servers
– ProLiant DL580 G7
– ProLiant BL620 G7
– ProLiant BL680 G7
How to disable “Processor Power and Utilization Monitoring”:
– enter BIOS (press F9 during boot)
– press CTRL+A (Service Option is hidden by default)
– select “Service Options” -> Processor Power and Utilization Monitoring -> Disable
– enter BIOS (press F9 during boot)
– press CTRL+A (Service Option is hidden by default)
– select “Service Options” -> Processor Power and Utilization Monitoring -> Disable
Press F10 to save and exit and reboot the server.
More information can be found on the next links:
https://bugs.centos.org/view.php?id=5493
http://h20565.www2.hp.com/hpsc/doc/public/display?sp4ts.oid=5227546&docId=emr_na-c03265132&lang=en&cc=us
https://bugs.centos.org/view.php?id=5493
http://h20565.www2.hp.com/hpsc/doc/public/display?sp4ts.oid=5227546&docId=emr_na-c03265132&lang=en&cc=us